SPECIFICATIONS


Capacity
Channels Per DSL             11          
Channels Per Shelf 132 (COT x 12)

High-Bit-Rate DSL (HDSL) Interface
Line code  2B1Q
Data Bit Rate 784 kb/s
Transmission 2-wirefull-duplex synchronous with adaptive echo cancellation and equalization
Loop Resistance 900 ohms
Impedance       135 ohms
Line Attenuation 31 dB @ 1SOkHz

VF Exchange Interface (COT)
Both 2-wire Loop Start and Leased line Interface
Input Impedance               600/900/Complex (£[)
Input Signal Level 3 dBmO maximum
Loop Current 20 to 80 mA
Ring Voltage  35 to 120 Vrms
Ring Frequency 20 to 30 Hz

VF Subscriber Interface (RT)

2-Wire Loop Interface
Input Impedance 600/900/Complex (£[)
Input Signal Level 3 dBmO maximum
Loop Current > 20mA
On-Hook DC voltage > 40 Vdc
RT Loop Resistance 820 ohms (include telephone set)
Ring Voltage  > 40 Vrms
Ring Load 3 REN per channel
Dialing signal  Pulse and DTMF
Dial Pulse Distortion < 3ms

Transmission Characteristics

Meet ITU-T G.712 Requirements
Insertion Loss   4.0 dB +/- 0.5
Return Loss > 15 dB@300 to 600 Hz
Channel Cross Talk < -70 FEXT
Idle Channel Noise  < -65 dBm0p
S/N Ratio > 33 dB@lkHz, 0dBm0 input level
On-Hook Transmission  < 6 dB

Metering Pulse Interface
Meter Pulse Frequency    16 or 12 kHz
Valid Frequency 16 or 12 kHz + 5%
RT Meter Pulse Signal  16 or 12 kHz + 1%

Indicators (LED)
COT   3 kinds of LED indication
ALRM (R) Alarm or controller failure
SYNC (G) On: HDSL is synchronized
Off Digital Subscriber line is open Flash: HDSL synchronization lost Flash slowly: Poor line quality
BSY (O) Indicate 11 channels status and alarm
RT            
        
           
PWR(R) Power is on
SYNC(G) On: HDSL is synchronized
Off: Digital Subscriber line is open
Flash: HDSLsynchronization lost Flash slowly: Poor line quality
MCU   Manage up to 8 COT shelves
LCD  2 x 16 dot matrix display
E-NET(G) Ethernet status indication
FAIL(R) Controller failure
ALARM Any alarm happened on shelves
ACO(O) Alarm cutoff
On-Board power -36 to -72 Vdc @ -48 Vdc nominal
Ambient Temperature
COT O to 45 C
RT -20 to +65 C
Humidity
COT O to 80% non-condensing
RT O to 95% non-condensing
Dimensions
COT shelf 48.2W x 22.2H x 36.OD cm(l9-inch)
RT 22.0W x 35.OH x 12.OD cm
MCU Shelf 48.2W, 4.5H x 32.OD cm

 